Gauge R&R — MSA
MeasureCrossed Gauge Repeatability and Reproducibility study using the ANOVA method. Quantifies measurement system variation relative to part-to-part variation and tolerance.
Data Entry
Enter one measurement per row: Part Operator Value
Lines starting with # are ignored. Paste directly from Excel.
Acceptability Criteria (AIAG MSA Manual)
Acceptable: %Study Variation < 10%
Marginal: 10% ≤ %Study Variation < 30%
Unacceptable: %Study Variation ≥ 30%
NDC ≥ 5 required for adequate discrimination.
Enter measurement data in the format Part Operator Value (one per row), then click Run Gauge R&R Analysis.